> For the complete documentation index, see [llms.txt](https://tech.jennyscience.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://tech.jennyscience.com/product-overview/linax-linear-motor-axes/linax-lxs-f120-shuttle.md).

# LINAX® Lxs F120 (shuttle)

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_070.jpg" alt=""><figcaption></figcaption></figure>

The Lxs Shuttle linear motor stages, designed for travel **distances up to 2'000 mm**, feature a "recessed" linear motor design and a **height of only 45mm** for the Lxs F120 model. A new, more potent motor is incorporated, boasting a nominal force of 120N and **peak performances up to 300N**. More robust guides facilitate the absorption of high force moments from transverse cantilever axes. The **innovative single-cable solution** simplifies installation and maintenance, while the **absolute measurement system**, which no longer requires a reference run, makes operation more efficient.

All the LINAX® Lxs linear motor stage can be controlled with the latest, more powerful XENAX® Xvi 75V8S servo controller. We recommend the use of a **Brake Recovery Unit (BERU)** in conjunction with these linear motor stages.

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_071.png" alt=""><figcaption></figcaption></figure>

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_072.png" alt=""><figcaption></figcaption></figure>

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_073.png" alt=""><figcaption></figcaption></figure>

<table data-full-width="false" data-search="false"><thead><tr><th>LINAX® Lxs F120 absolute</th><th align="center">Stroke [mm]</th><th align="center">Force Fn/Fp [N]</th><th align="center">Weight carriage slider/total [g]</th><th align="center">Art. No. meas. scale opt. 100nm +/- 0.5μm</th><th align="center">Art. No. meas. scale opt. 1µm +/- 1.5μm</th><th align="center">Art. No. meas. scale magn. 1µm +/- 2μm</th></tr></thead><tbody><tr><td><strong>Lxs 80F120*</strong></td><td align="center">080<br><em>(3.15")</em></td><td align="center">120/300<br><em>(27.0/67.4 lbf)</em></td><td align="center">2300/4700<br><em>(5.07/10.36 lbs)</em></td><td align="center"><strong>115.45.02</strong></td><td align="center"><strong>115.36.02</strong></td><td align="center"><strong>115.35.02</strong></td></tr><tr><td><strong>Lxs 200F120*</strong></td><td align="center">200<br><em>(7.87")</em></td><td align="center">120/300<br><em>(27.0/67.4 lbf)</em></td><td align="center">2300/5900<br><em>(5.07/13.00 lbs)</em></td><td align="center"><strong>115.45.08</strong></td><td align="center"><strong>115.36.08</strong></td><td align="center"><strong>115.35.08</strong></td></tr><tr><td><strong>Lxs 400F120</strong></td><td align="center">400 <em>(15.75")</em></td><td align="center">120/300<br><em>(27.0/67.4 lbf)</em></td><td align="center">2300/7800<br><em>(5.07/17.20 lbs)</em></td><td align="center"><strong>115.45.18</strong></td><td align="center"><strong>115.36.18</strong></td><td align="center"><strong>115.35.18</strong></td></tr><tr><td><strong>Lxs 520F120</strong></td><td align="center">520 <em>(20.47")</em></td><td align="center">120/300<br><em>(27.0/67.4 lbf)</em></td><td align="center">2300/9000<br><em>(5.07/19.84 lbs)</em></td><td align="center"><strong>115.45.24</strong></td><td align="center"><strong>115.36.24</strong></td><td align="center"><strong>115.35.24</strong></td></tr><tr><td><strong>Lxs 600F120</strong></td><td align="center">600 <em>(23.62")</em></td><td align="center">120/300<br><em>(27.0/67.4 lbf)</em></td><td align="center">2300/9800<br><em>(5.07/21.61 lbs)</em></td><td align="center"><strong>115.45.28</strong></td><td align="center"><strong>115.36.28</strong></td><td align="center"><strong>115.35.28</strong></td></tr><tr><td><strong>Lxs 800F120</strong></td><td align="center">800 <em>(31.50")</em></td><td align="center">120/300<br><em>(27.0/67.4 lbf)</em></td><td align="center">2300/11800<br><em>(5.07/26.01 lbs)</em></td><td align="center"><strong>115.45.38</strong></td><td align="center"><strong>115.36.38</strong></td><td align="center"><strong>115.35.38</strong></td></tr><tr><td><strong>Lxs 1000F120</strong></td><td align="center">1000 <em>(39.37")</em></td><td align="center">120/300<br><em>(27.0/67.4 lbf)</em></td><td align="center">2300/13700<br><em>(5.07/30.20 lbs)</em></td><td align="center"><strong>115.45.48</strong></td><td align="center"><strong>115.36.48</strong></td><td align="center"><strong>115.35.48</strong></td></tr><tr><td><strong>Lxs 1200F120</strong></td><td align="center">1200 <em>(47.24")</em></td><td align="center">120/300<br><em>(27.0/67.4 lbf)</em></td><td align="center">2300/15700<br><em>(5.07/34.61 lbs)</em></td><td align="center"><strong>115.45.58</strong></td><td align="center"><strong>115.36.58</strong></td><td align="center"><strong>115.35.58</strong></td></tr><tr><td><strong>Lxs 1600F120</strong></td><td align="center">1600 <em>(62.99")</em></td><td align="center">120/300<br><em>(27.0/67.4 lbf)</em></td><td align="center">2300/19600<br><em>(5.07/43.21 lbs)</em></td><td align="center"><strong>Coming soon</strong></td><td align="center"><strong>Coming soon</strong></td><td align="center"><strong>115.35.78</strong></td></tr><tr><td><strong>Lxs 2000F120</strong></td><td align="center">2000 <em>(78.74")</em></td><td align="center">120/300<br><em>(27.0/67.4 lbf)</em></td><td align="center">2300/23500<br><em>(5.07/51.82 lbs)</em></td><td align="center"><strong>Coming soon</strong></td><td align="center"><strong>Coming soon</strong></td><td align="center"><strong>115.35.88</strong></td></tr></tbody></table>

All versions listed are with **absolute measuring system**

\* These models are available with vertical weight compensation.

With an optical measuring system resolution of 100 nm, the maximum traversing speed is reduced to max. 0.9 m/s.

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_021.jpg" alt=""><figcaption></figcaption></figure>

**Note: LINAX® Lxs option cleanroom, food industry and pharmaceutical industry**The LINAX® Lxs can be mounted in clean room standard with additional charge of 10%. The ball bearing carriages are filled with a special lubrication. If you wish to use this option, please add the note ***„OPTION CLEANROOM/FOODINDUSTRIE/AND PHARMACEUTICAL INDUSTRY”*** (depending on your requirement) on your purchase order.

***

## s F120

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_074.png" alt=""><figcaption></figcaption></figure>

Absolutely revolutionary is the flexible one-cable connection, which reduces the machine cabling effort considerably. In only one cable are the lines for encoder, for the 3 phases of the linear motor and for the communication between LINAX® Lxs F120 and XENAX® Servocontroller.

These connection cables have a minimum bending radius of **48mm for continuous movement** and **of 20mm for fixed cables**. Extension cables are also available as accessories. The cable can withstand more than 1 million cycles of torsional stress at ±90° over a length of 1m

The connector housing can also be rotated in 90° grid.

<table data-full-width="false" data-search="false"><thead><tr><th>① Connecting- or extension cable XENAX® M16</th><th align="center">Length [m]</th><th align="center">15 Pol D-Sub Connector and 3 Pol Wago 3,5mm - M16 Plug Art. No.</th></tr></thead><tbody><tr><td><strong>TPU, Clean Room 5-6,</strong><br><strong>Suitable for cable chains,</strong><br><strong>Operating temp. -40° up to + 80°,</strong><br><strong>Ø 9.6mm</strong> <em>(0.38")</em></td><td align="center">1.5 <em>(59")</em><br>3.0 <em>(118")</em><br>5.0 <em>(197")</em><br>0.1-20 <em>(4" - 787")</em></td><td align="center"><strong>150.83.01</strong><br><strong>150.83.03</strong><br><strong>150.83.05</strong><br><strong>150.83.10</strong></td></tr></tbody></table>

<table data-full-width="false" data-search="false"><thead><tr><th>② Intermediate cable 2 x M16</th><th align="center">Length [m]</th><th align="center">M16 Socket – M16 Plug Art. No.</th></tr></thead><tbody><tr><td><strong>TPU, Clean Room 5-6,</strong><br><strong>Suitable for cable chains,</strong><br><strong>Operating temp. -40° up to + 80°,</strong><br><strong>Ø 9.6mm</strong> <em>(0.38")</em></td><td align="center">1.5 <em>(59")</em><br>3.5 <em>(138")</em><br>5.0 <em>(197")</em><br>0.1-20 <em>(4" - 787")</em></td><td align="center"><strong>150.84.01</strong><br><strong>150.84.03</strong><br><strong>150.84.05</strong><br><strong>150.84.10</strong></td></tr></tbody></table>

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_055.png" alt=""><figcaption></figcaption></figure>

Due to the limited access to the connector on the slide, tightening and loosening the connector can be difficult. To assist with this, Jenny Science AG offers a suitable installation tool as an accessory. This enables controlled tightening (≥1,2Nm) and easy loosening of the connector, even in confined installation spaces.

<table data-full-width="false" data-search="false"><thead><tr><th>Tightening tool M16</th><th align="center">Art. No.</th></tr></thead><tbody><tr><td><strong>Tightening tool M16 connector</strong></td><td align="center"><strong>151.09.20</strong></td></tr></tbody></table>

Connecting Cable LINAX® Lxs F120 with angled plug

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_075.png" alt=""><figcaption></figcaption></figure>

Depending on the installation situation, it may be useful to use an angled connector for the cable outlet on the motor side. The orientation of the cable can be specified in 45° steps - you can easily specify this orientation when ordering.

To do this, please select the desired cable and length using the article number and add the desired orientation variant. Without specific information, a 90° orientation is assumed as standard.

The orientation always refers to the standard outlet from the connector housing on the motor (“cable outlet on the right”, when viewed on the connector housing).

<table data-full-width="false" data-search="false"><thead><tr><th>① Connecting- or extension cable XENAX® M16 with angled plug</th><th align="center">Length [m]</th><th align="center">15 Pol D-Sub Connector and 3 Pol Wago 3,5mm - M16 Plug Art. No.</th><th align="center">Variant orientation</th><th align="center"></th></tr></thead><tbody><tr><td><strong>TPU, Clean Room 5-6,</strong><br><strong>Suitable for cable chains</strong><br><strong>Operating temp. -40° up to + 80°,</strong><br><strong>Ø 9.6mm</strong> <em>(0.38")</em></td><td align="center">0.1-20<br><em>(4" - 787")</em></td><td align="center"><strong>150.83.30</strong></td><td align="center"><blockquote><p><strong>90°</strong></p></blockquote></td><td align="center"><blockquote><p><strong>A</strong></p></blockquote></td></tr><tr><td></td><td align="center"></td><td align="center"></td><td align="center"><blockquote><p><strong>180°</strong></p></blockquote></td><td align="center"><blockquote><p><strong>B</strong></p></blockquote></td></tr><tr><td></td><td align="center"></td><td align="center"></td><td align="center"><blockquote><p><strong>0°</strong></p></blockquote></td><td align="center"><blockquote><p><strong>C</strong></p></blockquote></td></tr><tr><td></td><td align="center"></td><td align="center"></td><td align="center"><blockquote><p><strong>45°</strong></p></blockquote></td><td align="center"><blockquote><p><strong>D</strong></p></blockquote></td></tr><tr><td></td><td align="center"></td><td align="center"></td><td align="center"><blockquote><p><strong>135°</strong></p></blockquote></td><td align="center"><blockquote><p><strong>E</strong></p></blockquote></td></tr></tbody></table>

<table data-full-width="false" data-search="false"><thead><tr><th>② Intermediate cable 2 x M16 with angled plug</th><th align="center">Length [m]</th><th align="center">M16 Socket – M16 Plug Art. No.</th><th align="center">Variant orientation</th><th align="center"></th></tr></thead><tbody><tr><td><strong>TPU, Clean Room 5-6,</strong><br><strong>Suitable for cable chains</strong><br><strong>Operating temp. -40° up to + 80°,</strong><br><strong>Ø 9.6mm</strong> <em>(0.38")</em></td><td align="center">1.5 <em>(59")</em><br>3.5 <em>(138")</em><br>5.0 <em>(197")</em><br>0.1-20 <em>(4" - 787")</em></td><td align="center"><strong>150.84.21</strong><br><strong>150.84.23</strong><br><strong>150.84.25</strong><br><strong>150.84.30</strong></td><td align="center"><blockquote><p><strong>90°</strong></p></blockquote><blockquote><p><strong>180°</strong></p></blockquote><blockquote><p><strong>0°</strong></p></blockquote><blockquote><p><strong>45°</strong></p></blockquote><blockquote><p><strong>135°</strong></p></blockquote></td><td align="center"><blockquote><p><strong>A</strong></p></blockquote><blockquote><p><strong>B</strong></p></blockquote><blockquote><p><strong>C</strong></p></blockquote><blockquote><p><strong>D</strong></p></blockquote><blockquote><p><strong>E</strong></p></blockquote></td></tr></tbody></table>

***

## Vertical Weight Compensation LINAX® Lxs F120

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_076.png" alt=""><figcaption></figcaption></figure>

In case of a power interruption, the linear motor of the LINAX® axis is powerless. If the axis is applied vertically, the slider of the linear motor would fall downwards. With this weight compensation based on compressed air without air consumption, the slider remains in position or moves upwards depending on the air adjustment. For adjustment of the air pressure use a commercial **air pressure regulator**, for example Festo ”VRPA“. The air pressure coupling is on the 90° “rotatable” connector case.

A great advantage of the weight compensation is the support of the linear motor in vertical orientation. The motor runs without a static weight and is not heating in a stationary position. You get higher dynamics and at the same time you also save energy.

<table data-full-width="false" data-search="false"><thead><tr><th>Weight compensation Lxs F120</th><th align="center">Maximal force at 6 bar</th><th align="center">Art. No.</th></tr></thead><tbody><tr><td><strong>Lxs 80F120</strong><br><strong>Lxs 200F120</strong></td><td align="center">12 kg <em>(26.5lbs)</em></td><td align="center"><strong>135.04.01</strong><br><strong>135.04.05</strong></td></tr></tbody></table>

***

## Fixings screws for ground plate LINAX® Lxs F120

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_077.png" alt=""><figcaption></figcaption></figure>

<table data-full-width="false" data-search="false"><thead><tr><th>Linear Motor Type</th><th align="center">Screws</th><th align="center">Art. No.</th></tr></thead><tbody><tr><td><strong>Fixing screws</strong><br><strong>Lxs F120</strong></td><td align="center">10 x hexagon socket screws M4 x 20mm <em>(0.79")</em><br>stainless</td><td align="center"><strong>135.11.07</strong></td></tr></tbody></table>

*Lxs 80F120 = 2 Sets Lxs 800F120 = 5 Sets*

*Lxs 200F120 = 2 Sets Lxs 1000F120 = 6 Sets*

*Lxs 400F120 = 3 Sets Lxs 1200F120 = 7 Sets*

*Lxs 520F120 = 4 Sets Lxs 1600F120 = 9 Sets*

*Lxs 600F120 = 4 Sets Lxs 2000F120 = 11 Sets*

***

## Cross table fixing screws LINAX® Lxs F120

<table data-header-hidden data-full-width="false" data-search="false"><thead><tr><th></th><th align="center"></th><th align="center"></th></tr></thead><tbody><tr><td>Linear Motor Type</td><td align="center">Screws and centering pins</td><td align="center"><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_078.png" alt=""></td></tr><tr><td><strong>Cross table set</strong><br><strong>Lxs F120</strong></td><td align="center">6 x hexagon socket screws M4 x 20mm <em>(0.79")</em>,<br>4 x centering pins<br>Ø4mm <em>(0.16")</em> h8 x 8mm <em>(0.31")</em><br>stainless</td><td align="center"><strong>135.11.25</strong></td></tr></tbody></table>

The various LINAX® linear motor types can be directly mounted to each other without the need of adapter plates. For cross table combinations there are multiple grid patterns possible.

For the choice of the according screws, the upper mounted linear motor is relevant.

***

## Cover tape for screws of ground plate LINAX® Lxs F120

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_079.png" alt=""><figcaption></figcaption></figure>

<table data-full-width="false" data-search="false"><thead><tr><th>Linear Motor Type</th><th align="center">Cover tape set</th><th align="center">Art. No.</th></tr></thead><tbody><tr><td><strong>Lxs 80F120</strong></td><td align="center">The cover tape set includes 2 tapes to cover both sides.</td><td align="center"><strong>135.08.02</strong></td></tr><tr><td><strong>Lxs 200F120</strong></td><td align="center"></td><td align="center"><strong>135.08.04</strong></td></tr><tr><td><strong>Lxs 400F120</strong></td><td align="center"></td><td align="center"><strong>135.08.10</strong></td></tr><tr><td><strong>Lxs 520F120</strong></td><td align="center"></td><td align="center"><strong>135.08.12</strong></td></tr><tr><td><strong>Lxs 600F120</strong></td><td align="center"></td><td align="center"><strong>135.08.14</strong></td></tr><tr><td><strong>Lxs 800F120</strong></td><td align="center"></td><td align="center"><strong>135.08.16</strong></td></tr><tr><td><strong>Lxs 1000F120</strong></td><td align="center"></td><td align="center"><strong>135.08.18</strong></td></tr><tr><td><strong>Lxs 1200F120</strong></td><td align="center"></td><td align="center"><strong>135.08.20</strong></td></tr><tr><td><strong>Lxs 1600F120</strong></td><td align="center"></td><td align="center"><strong>135.08.22</strong></td></tr><tr><td><strong>Lxs 2000F120</strong></td><td align="center"></td><td align="center"><strong>135.08.24</strong></td></tr></tbody></table>

<figure><img src="https://raw.githubusercontent.com/JennyScience-AG/tech-images/main/ProductCatalog_080.png" alt=""><figcaption></figcaption></figure>

***

## Additional carriage slider LINAX® Lxs F120

With the LINAX® Lxs linear motor axes it is possible to assemble two or more carriage sliders on the same ground plate. The cable connector can be orientated on the left or right side of the slider. Each carriage slider requires a XENAX® servo controller.

<table data-full-width="false" data-search="false"><thead><tr><th>Additional carriage slider LINAX® Lxs F120</th><th align="center">Type of carriage slider</th><th align="center">Art. No.</th></tr></thead><tbody><tr><td><strong>Lxs xxxF120 mag. 1 µm</strong></td><td align="center">Carriage slider to LINAX® Lxs "shuttle" F120 with precise, self-lubricating ball bearing carriages, integrated<br><strong>absolute magnetic measuring system</strong><br>resolution 1 µm, accuracy +/-2µm</td><td align="center"><strong>135.30.30</strong></td></tr><tr><td><strong>Lxs xxxF120 opt. 1 µm</strong></td><td align="center">Carriage slider to LINAX® Lxs "shuttle" F120 with precise, self-lubricating ball bearing carriages, integrated<br><strong>absolute optical measuring system</strong><br>resolution 1 µm, accuracy +/-1.5µm</td><td align="center"><strong>135.30.32</strong></td></tr><tr><td><strong>Lxs xxxF120 opt. 100 nm</strong></td><td align="center">Carriage slider to LINAX® Lxs "shuttle" F120 with precise, self-lubricating ball bearing carriages, integrated<br><strong>absolute optical measuring system</strong><br>resolution 100 nm, accuracy +/-0.5µm</td><td align="center"><strong>135.30.34</strong></td></tr><tr><td><strong>Lxs xxxF120 passiv</strong></td><td align="center">Passive carriage slider with precise, self-lubricating ball bearing carriages.<br>WITHOUT MOTOR &#x26; WITHOUT MEASURING SYSTEM<br>Does not require servo controller</td><td align="center"><strong>135.30.36</strong></td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://tech.jennyscience.com/product-overview/linax-linear-motor-axes/linax-lxs-f120-shuttle.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.